Improved cookstoves in rural Odisha
Environment and climate · Odisha · Stoves built from September 2006 to April 2010, with households followed for four years after the first offers
The intervention
Gram Vikas, an NGO, offered subsidised improved mud stoves with a chimney and two pot holes (the ARTI design, about US$12.50 per stove) to households chosen by public lottery in each village. Stove construction came with training on use and maintenance and a paid village promoter.
Verdict
The stoves aimed to cut smoke exposure and improve health. Exhaled carbon monoxide among primary cooks fell by 3.1 percent of the control mean over the four years, which is not statistically significant. The only significant fall was 0.53 ppm (7.5 percent) in year 1, and it was gone by year 2. A standardised index of health outcomes moved by 0.008 standard deviations for primary cooks (standard error 0.014), and lung function, birth weight and illness showed no gains. Wood use and fuel costs did not fall, and repairs rose by 2.431 per year.
The main study found no significant improvement in the targeted outcome, or found harm.
The study
- Design
- Randomised trial. Within each village a public lottery decided the order in which households received stoves, in three waves. Households offered a stove in the first two waves are compared with households still waiting. Standard errors are clustered at the household level and effects are estimated by months since stove construction.
- Sample
- 2,575 households in 44 villages in the western and southern districts of Odisha (then Orissa), followed for four years. About 94 percent of households were found in the first two main surveys and about 81 percent in the last.
Results
| Outcome | Result | Uncertainty | Where in the source |
|---|---|---|---|
| Meals cooked in a week on a good-condition, low-polluting stove (offered versus not offered) | The extra meals fell from 3.472 in year 1 to 1.758 by year 3. | Standard error 0.229 in year 1 and 0.287 in year 3 (Table 3, column 4) | Section IV.A, Table 3 column 4 |
| Households with an improved stove installed | Households offered a stove were 62 percentage points more likely to have the improved stove than the control group. | Standard error 0.011 (Table 3, column 1) | Section IV.A, Table 3 column 1 |
| Improved stoves in good condition | The offer raised the share of improved stoves in good condition by 36 percentage points over the whole period. | Standard error 0.011 (Table 3, column 3) | Section IV.A, Table 3 column 3 |
| Exhaled carbon monoxide of primary cooks, four-year average | Carbon monoxide fell by 3.1 percent of the control mean, which is not statistically significant. | Coefficient -0.230 ppm, standard error 0.196; control mean 7.128 ppm (Table 4, column 1) | Section IV.B, Table 4 column 1 |
| Exhaled carbon monoxide of primary cooks, year 1 | In year 1 the reduction was 0.53 ppm, or 7.5 percent of the control mean, when stove use was at its highest. | Coefficient -0.534 ppm, standard error 0.281, significant at the 10 percent level only (Table 4, panel B) | Section IV.B, Table 4 panel B |
| Exhaled carbon monoxide of primary cooks, years 2 to 4 | The effect fell to 0.173 ppm by the second year, was no longer significant, and was positive and insignificant in years 3 and 4. | Year 2 standard error 0.489 (Table 4, panel B) | Section IV.B, Table 4 panel B |
| Exhaled carbon monoxide of children | Carbon monoxide among children fell slightly, which is not statistically significant. | Coefficient -0.120 ppm, standard error 0.181; control mean 5.460 ppm (Table 4, column 2) | Section IV.B, Table 4 column 2 |
| Lung function of women who cook regularly (spirometry) | No difference in lung function between treatment and control women. | Not reported | Introduction; Section IV.C, Table 6A |
| Standardised index of health outcomes | The index changed by a 0.008 standard deviation fall for primary cooks and a 0.006 rise for children, neither significant. | Standard error 0.014 for primary cooks and 0.011 for children (Table 6B, panel A) | Section IV.C, Table 6B panel A |
| Wood used at the last meal (kg) | Wood use did not change: the estimate is 0.046 kg. | Standard error 0.123; control mean 3.373 kg (Table 7, column 1) | Section IV.D, Table 7 column 1 |
| Fuel costs in the last 30 days (rupees) | Reported fuel spending rose by 9.482 rupees, which is not statistically significant. | Standard error 6.697; control mean 333 rupees (Table 7, column 2) | Section IV.D, Table 7 column 2 |
| Repairs made to the stove in the last year | Treatment households made 2.431 more repairs per year. | Standard error 0.506, significant at the 1 percent level; control mean 5.430 (Table 7, column 4) | Section IV.D, Table 7 column 4 |
Quotations from the source
This fell from 3.472 in Year 1 to 1.758 by Year 3.
the treatment group was 62 percentage points more likely to have a GV stove than the control group
the treatment effect on the proportion of GV improved stoves in good condition is 36 percentage points over the entire period
In terms of magnitude, it is small, being 3.1 percent of the mean and 3.6 percent of a standard deviation.
we find a 0.53 ppm reduction (7.5 percent of the control group’s mean) in the CO concentration during Year 1 for primary cooks
the treatment effect for primary cooks falls to −0.173 ppm by the second year of stove ownership and is no longer significant, and is positive and insignificant by Years 3 and 4
For children, the overall effect is also negative, but statistically insignificant
no difference in lung functioning (as measured by spirometry tests) between women who regularly cook in the treatment and control groups
Treat −0.008 0.006
Treat 0.046 9.482 3.410 2.431*** 29.387**
Treat 0.046 9.482 3.410 2.431*** 29.387**
Treat 0.046 9.482 3.410 2.431*** 29.387**
Limits of the evidence
- Smoke exposure is measured by carbon monoxide in exhaled breath, a proxy for fine particles, not by direct measurement of fine particles.
- The stove is at the lower-cost end of improved designs, and the authors note that stove designs have improved since the study began.
- The programme was run by a well-regarded NGO with training and a village promoter, so the authors describe it as a better-than-typical rollout.
- The finding concerns stoves that households used irregularly and maintained poorly. It does not show what a stove that is well used and maintained would do.
- Cited from the published article as hosted by J-PAL.
Sources
- Hanna, R., Duflo, E. and Greenstone, M. (2016). Up in Smoke: The Influence of Household Behavior on the Long-Run Impact of Improved Cooking Stoves. American Economic Journal: Economic Policy 8(1): 80-114. Published version, as hosted by J-PAL.. https://www.povertyactionlab.org/sites/default/files/research-paper/52%20Up%20in%20Smoke%20AEJ2016.pdf
Figures checked against the sources above on 2026-10-27.